AQ-L397 Line protection device
AQ300_full rack_web_2
AQ300_full rack_web_2

Description

AQ-L397 is a line protection device with full scheme distance protection for transmission and sub-transmission line protection applications. It integrates a full range of line protection functions as well as a variety of additional functions for control, measurement, monitoring and communications.

Highlights:

  • Distance protection with polygon or MHO characteristics.
  • Impedance measuring in six separate loops for phase or earth faults.
  • Parallel line zero sequence current compensation.
  • Load encroachment and power swing block characteristics.
  • Zone 1 sub-cycle trip time.
AQ300_full rack_web_2

Technical data

  • Three-phase instantaneous/time overcurrent (I>; 50/51)
  • Residual instantaneous/time overcurrent (I0>; 50N/51N)
  • Directional three-phase overcurrent (Idir>; 67)
  • Directional residual overcurrent (I0dir>; 67N/32N)
  • Negative sequence overcurrent/ Current unbalance (I2>; 46)
  • Thermal overload (T>; 49)
  • Overvoltage (U>; 59)
  • Undervoltage (U>; 27)
  • Residual overvoltage (U0>; 59N)
  • Over- and underfrequency (f>/<; 81O/81U)
  • Rate-of-change of frequency (df/dt; 81R)
  • Circuit breaker failure protection (CBFP; 50BF/52BF)
  • Teleprotection (85)
  • Inrush detection and blocking
  • Stub protection
  • Weak-end infeed protection
  • Distance protection
  • Distributed busbar protection (sub-unit) (optional)

  • Common function
  • Trip logic (94)
  • Dead line detection
  • Synchrocheck (ΔV/Δa/Δf; 25)
  • Auto-recloser (0 → 1; 79)
  • Switch-on-to-fault
  • Voltage variation

  • Current (IL1, IL2, IL3, I0)
  • Voltage (U1, U2, U3, U12, U23, U31, U0) and frequency (f)
  • Power (P, Q, S, pf) and Energy (E+, E-, Eq+, Eq-)
  • Current transformer supervision
  • Voltage transformer supervision (60)
  • Trip circuit supervision
  • Switching device status monitoring
  • Event recorder
  • Disturbance recorder

  • Standard
  • CPU module (MM/ST + RJ-45)
  • Power supply module (PS + fault relay + 2 trips)
  • Current measurement module
  • Voltage measurement module
  • Number of supervised trip contacts: 4
  • Number of empty slots: 16
  • Options
  • 6 digital inputs (1x6) + 5 digital outputs
  • 8 digital inputs (1x8)
  • 12 digital inputs (3x4)
  • 16 digital inputs (2x8)
  • 9 digital inputs (3x3) with IRIG-B (BNC)
  • 8 digital outputs (1x8)
  • 12 digital outputs (4x3)
  • 16 digital outputs (2x8)
  • 4-channel RTD module
  • 4-channel analogue input module (2-wire)

  • Communication inputs
  • ST/MM fiber optic Ethernet and RS-485 (optional)
  • 2 x ST/MM redundant fiber optic Ethernet (optional)
  • ST/MM fiber optic Ethernet and RS-485 (optional)
  • LC/MM and RJ-45 (optional)
  • 2 x LC/MM (optional)
  • Line differential communication SM/FC (0-50 km) (optional)
  • Line differential communication SM/FC (10...120 km) (optional)
  • PRP/HSR (optional)
  • Communication protocols
  • IEC 60870-5-101/104/103
  • Modbus/RTU and Modbus/TCP
  • DNP3.0
  • IEC 61850 (optional)

  • PMU capability (optional)
  • Advanced "CyberProtect" cyber security feature (optional)

Related products

Ask for an offer or more information

We provide a comprehensive range of services through our own skilled staff and a global network of partners.

Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.

Strictly Necessary Cookies

Strictly Necessary Cookie should be enabled at all times so that we can save your preferences for cookie settings.

3rd Party Cookies

This website uses Google Analytics to collect anonymous information such as the number of visitors to the site, and the most popular pages.

Keeping this cookie enabled helps us to improve our website.