AQ-103 Arc flash protection device
AQ-103_front_web
AQ-103_front_web

Description

AQ-103 Arc flash protection device is a sophisticated microprocessor-based arc flash protection device for arc light detection. It is designed to minimize the damage caused by an arcing fault (arc flash) by tripping the circuit breaker that sources the fault current. The complete system self-supervision function of AQ-103 provides the highest level of dependability by continuously monitoring all internal system functions as well as with external connections.

The AQ-103 arc flash protection device acts as a sub-unit to AQ-110P (or, AQ-110F) in an AQ 100 arc protection system. It can also function as a stand-alone unit in light-only systems. Additionally, AQ-103 can provide Modbus RTU communication via an RS-485 port. Through Modbus communication, AQ-103 connects to a local display (AQ-S254A) for indication of exact fault location and to a SCADA system either through an AQ-S254 device or a remote terminal unit (RTU).

Highlights:
  • A wide range for the power supply (18…72 V DC or 92…265 V AC/DC).
  • Max. 14 fiber loop sensors per device (1 sensor/channel).
  • 4 trip relays (with 7 ms total trip time).
  • Complete system self-supervision.
  • 2 binary inputs, 1 binary output, and 1 high-speed output.
  • A multifunction push button (“SET”) with auto-configuration, indication reset, and system check.
  • 25 indication LEDs.
  • Modbus RTU communication (optional).

Learn more about how different protection techniques affect the consequences of an arc flash:

“Arc flash comparison” by Arcteq Relays (https://youtu.be/EUlZ_a_rcIg)

AQ-103_front_web

Technical data

  • Light only
  • Light and pressure
  • Circuit breaker failure protection (50BF/52BF)
  • Total trip time: 7 ms

  • AQ-01 light sensor (activation thresholds: 8 klx, 15 klx, 50 klx)
  • AQ-02 light and pressure sensor (activation thresholds: 8 klx, 15 klx, 50 klx)
  • AQ-06 plastic fiber sensor (3...40 m)
  • AQ-07 glass fiber sensor (3...50 m length)
  • AQ-08 glass fiber sensor (3...15 m)

  • Trip relays (T1, T2, T3, T4)
  • 4 NO or 3 NO + 1 NC
  • Rated voltage: 250 V AC/DC
  • Continuous carry: 5 A
  • Make-and-carry for 3 s: 16 A
  • Make-and-carry for 0.5 s: 30 A
  • Binary output (BO1)
  • Number of outputs: 1
  • Rated voltage: +24 V DC
  • Binary inputs (BI1, BI2)
  • Number of inputs: 2
  • Threshold voltage: 24 V DC
  • Rated voltage: 250 V AC/DC
  • Power supply
  • Auxiliary power supply: 92…265 V AC/DC
  • Auxiliary power supply: 18…72 V DC (optional)

  • 25 indication LEDs
  • Multi-function push button (SET) with auto-configuration, indication reset, and system check

  • Internal functions:
  • Power supply
  • Trip coil
  • Internal voltages
  • Settings
  • External connections:
  • Sensors and wiring
  • Binary I/O

  • Modbus RTU

  • AQ 100 series
  • AQ 200 series
  • AQ 300 series

  • AX006 Wall mounting bracket

Additional material

Application Drawing

103 wiring diagrams

Related products

Ask for an offer or more information

We provide a comprehensive range of services through our own skilled staff and a global network of partners.

Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.

Strictly Necessary Cookies

Strictly Necessary Cookie should be enabled at all times so that we can save your preferences for cookie settings.

3rd Party Cookies

This website uses Google Analytics to collect anonymous information such as the number of visitors to the site, and the most popular pages.

Keeping this cookie enabled helps us to improve our website.